Chilled Water Cassette Type Fan Coil Unit

Air volume: 200 CFM to 1400 CFM (340 m3/h to 2380m3/h)
Cooling capacity: 1.8 kW to 12.6 kW
Heating capacity: 2.98 kW to 18.9 kW
4 pipes can be customized.

分类:

描述

The cassette type fan coil unit is the terminal unit that directly delivers cold and hot air to the room through external cooling and hot water. It has the functions of cooling, heating or cooling/heating respectively. It is mainly composed of a volute centrifugal fan, heat exchanger coil, fan motor, condensation pan and galvanized sheet casing, it is a universal terminal device for the water-type central air conditioning and heat pump systems.

The cassette fan coil unit, also called a ceiling-type fan coil unit, has an air volume ranging from 340m’/h to 2380m’/h(high speed). This FCU is ceiling mounted with 4-way air outlets and wide-angle air supply. Only the air inlet/outlet panel is exposed outside the ceiling. The panel is beautiful, and the height is only 300-320mm. It does not take up space and is easy to maintain.

With condensation drainage pump and remote controller, the drainage pump’s lift is 85cm, and the thermostat is optional with  the remote controller.

The Cassette fan coil unit could be designed into 2 tubes & 4 tubes, applicable to hotel halls, shopping malls, meeting rooms and other public scenes.

Features of cassette-type fan coil unit:

1. The fan coil unit with thin design with total heiht 300-320mm.
2. Standard type with remote controller while the thermostat is optional.
3. “C” type Hydrophilic aluminum fins heat exchanger.
4. With 4-way air outlets, wide-angle air supply.
5. Large diameter vortex centrifugal fan, low noise operation.
6. With 2 tubes & 4 tubes design, optional for clients.
7. With washable air filter which is easy to clean & change.

 

Cassette Type Fan Coil Unit(4-Way, 2 Tubes)

Model  GLCT- 34KM 51KM 68KM 85KM 102KM 136KM 170KM 204KM 238KM
Air volume CFM 200 300 400 500 600 800 1000 1200 1400
H m³/h 340 510 680 850 1020 1360 1700 2040 2380
M m³/h 280 390 520 640 790 1030 1290 1550 1800
L m³/h 180 260 350 430 520 690 860 1050 1200
Cooling capacity H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
M W 1631 2279 2814 3750 4322 5534 7512 8088 9681
L W 1048 1519 1894 2519 2854 3694 5008 5554 6454
Heating capacity H W 2980 4800 5480 7200 8180 10800 14500 16200 18900
M W 2454 3671 4191 5421 6335 8179 11005 12353 14521
L W 1578 2447 2821 3600 4170 5479 7335 8482 9681
Noise dB(A) 34/36/37 35/37/39 37/39/41 39/40/43 40/43/45 41/44/46 41/45/47 43/46/49 44/48/52
Power input W 38 58 68 82 102 134 138 162 211
Waterflow volume m³/h 0.42 0.52 0.62 0.86 0.98 1.08 1.58 1.78 1.92
Water Resistance kPa 14 14 16 18 22 25 39 44 46
Connection pipe in/out DN20
Drain ∮26mm
Casing Panel Thickness ABS injection molded panel 4mm
Sheet metal case Thickness Galvanized sheet layer, basin 1.2mm, side plate 0.75mm
Foam water pan Density Flame-retardant material polystyrene content 35kg/m³
Fan Impeller Diameter 315mm 380mm 480mm
Heat Exchanger Type High efficient copper pipe to wear Hydrophilic aluminum coil
Al fins Thickness 0.12mm
Copper tube QTY 9.52*0.28 12 14 16 14 16 18 16 18 20
Waterway in/out 3 in 3 out 4 in 4 out
Dimension(Before bending) 1150*200*43 1680*225*43 2090*250*43
Unit Dimension L×W×H          mm 650*650*300 800*800*310 950*950*320
Packing Dimension 720*720*360 860*860*370 1000*1000*380
Weight kg 24 24.5 25 33 34 35 43 44 45

Condition:
1. Cooling: Indoors DB 27℃, WB 19.5℃; Chilled water inlet/outlet temp.12℃/7℃.
2. Heating: Indoors DB WB 20℃, heating water inlet&outlet temperature 60℃/50°C.
3. The noise level based on: background noise 11.5Db(A) semi-anechoic room.

 

 